Research progress in measurement of biological parameters of anterior segment
-
摘要: 准确的眼前节生物参数测量对精确的屈光手术、白内障手术、青光眼的诊治等都有重要的参考价值。近年来,眼前节生物参数测量仪器发展迅速,由裂隙灯检查到超声生物显微镜(UBM)、前节光学断层扫描(AS-OCT)、眼前节生物测量仪Lenstar LS900和三维眼前节分析系统Pentacam等,测量的数据越来越丰富,精确度也有所提高。本研究对临床上常使用的几种眼前节参数测量仪器的原理、特点及临床应用进行综述。Abstract: Accurate measurement of biological parameters of anterior segment has an important reference value for accurate refractive surgery, cataract surgery, and diagnosis and treatment of glaucoma. In recent years, the instruments for measurement of biological parameters of anterior segment have developed rapidly from slit lamp examination to ultrasonic biomicroscope(UBM), anterior segment optical coherence tomography(AS-OCT), optical biometry measurement device(Lenstar LS900)and equipment of Pentacam. With the development of instruments, the measurement data is more and more abundant, and the accuracy is also improved. In this study, the principles, characteristics and clinical applications of several commonly used instruments for measurement of biological parameters of anterior segment are reviewed.
-
-
宋文晓, 卢广文. 眼球生物测量的应用进展[J]. 临床医学工程, 2011, 18(4): 629-631. 解蕊, 原文新, 芦利娟, 等. 晶星900与A超生物测量对比研究[J]. 中国实用眼科杂志, 2014, 32(11): 1306-1308. KRONBAUER A L, KRONBAUER F L, KRONBAUER C L. Comparative study of the biometric measurements made by immersion and contact techniques[J]. Arq Bras Oftalmol, 2006, 69(6): 875-880.
杨文利. 超声生物显微镜检查法[J]. 眼科研究, 2006, 24(5): 449-451. 王瑞娜, 郑广瑛, 王松田, 等. UBM量化观察有晶状体眼后房型人工晶状体植入术前后眼前节形态的变化[J]. 中华眼科杂志, 2011, 47(9): 815-819. TORRES V L L, ALLEMANN N, ERWENNE C M. Ultrasound biomicroscopy features of Iris and ciliary body melanomas before and after brachytherapy[J]. Ophthalmic Surg Lasers Imaging Retina, 2005, 36(2): 129-138.
KONSTANTOPOULOS A, HOSSAIN P, ANDERSON D F. Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis?[J]. Br J Ophthalmol, 2007, 91(4): 551-557.
DADA T, SIHOTA R, GADIA R, et al. Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment[J]. J Cataract Refract Surg, 2007, 33(5): 837-840.
RADHAKRISHNAN S, GOLDSMITH J, HUANG D, et al. Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles[J]. Arch Ophthalmol, 2005, 123(8): 1053-1059.
SAKUMA T, SAWADA A, YAMAMOTO T, et al. Appositional angle closure in eyes with narrow angles: an ultrasound biomicroscopic study[J]. J Glaucoma, 1997, 6(3): 165-169.
RADHAKRISHNAN S, HUANG D. Optical coherence tomography imaging of the anterior chamber angle[J]. Ophthalmology clinics of North America, 2005, 18(3): 375-381.
张鹏, 艾明. 眼前节参数生物测量的临床研究进展[J]. 临床眼科杂志, 2017, 25(5): 475-479. KIM H Y, BUDENZ D L, LEE P S, et al. Comparison of central corneal thickness using anterior segment optical coherence tomography vs ultrasound pachymetry[J]. Am J Ophthalmol, 2008, 145(2): 228-232.
邹湖涌, 刘志平, 沙翔垠, 等. 三种仪器测量中央及周边角膜厚度的比较[J]. 中华眼科医学杂志: 电子版, 2016, 6(2): 55-60. 李栋, 贾志杰, 张海宁, 等. Pentacam及前节OCT在测量中央角膜厚度上的比较[J]. 临床医药文献电子杂志, 2019, 6(30): 85-86. 周行涛, 褚仁远. 眼前节全景仪[M]. 上海: 复旦大学出版社, 2009: 1-4. ZHAO J, CHEN Z, ZHOU Z M, et al. Evaluation of the repeatability of the Lenstar and comparison with two other non-contact biometric devices in myopes[J]. Clin Exp Optom, 2013, 96(1): 92-99.
郭家箭, 杨根兰, 饶丹, 等. 散瞳对pentacam生物测量的影响[J]. 赣南医学院学报, 2019, 39(9): 911-913. LAVANYA R, WONG T Y, FRIEDMAN D S, et al. Determinants of angle closure in older Singaporeans[J]. Arch Ophthalmol, 2008, 126(5): 686-691.
KASWIN G, ROUSSEAU A, MGARRECH M, et al. Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard[J]. J Cataract Refract Surg, 2014, 40(4): 593-600.
AKMAN A, ASENA L, GÜNGÖR S G. Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500[J]. Br J Ophthalmol, 2016, 100(9): 1201-1205.
陈伟, 杨文利, 李栋军, 等. 不同型号IOL Master对硅油眼的生物测量比较[J]. 眼科, 2018, 27(5): 349-352. FONTES B M, FONTES B M, CASTRO E. Intraocular lens power calculation by measuring axial length with partial optical coherence and ultrasonic biometry[J]. Arq Bras Oftalmol, 2011, 74(3): 166-170.
ARRIOLA-VILLALOBOS P, ALMENDRAL-GÓMEZ J, GARZÓN N, et al. Agreement and clinical comparison between a new swept-source optical coherence tomography-based optical biometer and an optical low-coherence reflectometry biometer[J]. Eye(Lond), 2017, 31(3): 437-442.
SONG J S, YOON D Y, HYON J Y, et al. Comparison of ocular biometry and refractive outcomes using IOL master 500, IOL master 700, and lenstar LS900[J]. Korean J Ophthalmol, 2020, 34(2): 126-132.
CRUYSBERG L P, DOORS M, VERBAKEL F, et al. Evaluation of the Lenstar LS 900 non-contact biometer[J]. Br J Ophthalmol, 2010, 94(1): 106-110.
ROHRER K, FRUEH BE, WÄLTI R, et al. Comparison and evaluation of ocular biometry using a new noncontact optical low-coherence reflectometer[J]. Ophthalmology, 2009, 116(11): 2087-2092.
BUCKHURST PJ, WOLFFSOHN JS, SHAH S, et al. A new optical low coherence reflectometry device for ocular biometry in cataract patients[J]. The British journal of ophthalmology, 2009, 93(7): 949-953.
-
期刊类型引用(3)
1. 吴宝红,李莺. 一次性超声生物显微镜检查受水袋的制作及应用. 国际护理学杂志. 2024(17): 3222-3224 . 百度学术
2. 张敏,安广琪,刘培,杨帆,金波,金学民,杜利平. 基于SS-OCT分析眼轴长度与眼前节参数的相关性. 国际眼科杂志. 2023(08): 1338-1342 . 百度学术
3. 胡雅斌,魏文斌,翟长斌,张丽,付彩云,郑燕. FAL-1000A与Lenstar LS 900对眼生物学参数测量结果的一致性分析. 中华眼视光学与视觉科学杂志. 2023(09): 665-670 . 百度学术
其他类型引用(3)
计量
- 文章访问数: 540
- HTML全文浏览量: 138
- PDF下载量: 58
- 被引次数: 6