动态血糖监测联合胰岛素泵强化治疗2型糖尿病疗效及安全性评价

陈丽

陈丽. 动态血糖监测联合胰岛素泵强化治疗2型糖尿病疗效及安全性评价[J]. 实用临床医药杂志, 2014, (1): 53-55. DOI: 10.7619/jcmp.201401016
引用本文: 陈丽. 动态血糖监测联合胰岛素泵强化治疗2型糖尿病疗效及安全性评价[J]. 实用临床医药杂志, 2014, (1): 53-55. DOI: 10.7619/jcmp.201401016
CHEN Li. Efficacy and Security of dynamic glucose monitoring combined with continuous subcutaneous insulin infusion in treatment of patients with type 2 diabetes mellitus[J]. Journal of Clinical Medicine in Practice, 2014, (1): 53-55. DOI: 10.7619/jcmp.201401016
Citation: CHEN Li. Efficacy and Security of dynamic glucose monitoring combined with continuous subcutaneous insulin infusion in treatment of patients with type 2 diabetes mellitus[J]. Journal of Clinical Medicine in Practice, 2014, (1): 53-55. DOI: 10.7619/jcmp.201401016

动态血糖监测联合胰岛素泵强化治疗2型糖尿病疗效及安全性评价

基金项目: 中国高校医学期刊临床专项资金
详细信息
  • 中图分类号: R587.1

Efficacy and Security of dynamic glucose monitoring combined with continuous subcutaneous insulin infusion in treatment of patients with type 2 diabetes mellitus

  • 摘要: 目的 分析动态血糖监测联合胰岛素泵强化治疗2型糖尿病(T2DM)的临床疗效及安全性.方法 将88例T2DM患者随机分为观察组和对照组,每组44例.观察组采用动态血糖监测系统(CGMS)联合胰岛素泵持续皮下输注(CSI-I),即“双C”疗法进行治疗,对照组仅采用CSII进行治疗,比较2组患者治疗前后血糖水平的变化、血糖达标时间、胰岛素用量及低血糖事件的发生情况.结果 治疗后,2组患者的空腹血糖(FBG)和2h餐后血糖(2 hPG)均较治疗前明显降低;观察组患者胰岛素用量及血糖达标时间均显著低于对照组,差异有统计学意义;治疗期间,观察组有8例患者出现低血糖,均无其他伴随症状,对照组有18例患者出现低血糖,均伴有冷汗、心慌等症状,2组低血糖发生率比较差异显著.结论 “双C”疗法可有效降低T2DM患者的血糖水平,减少胰岛素用量及缩短血糖达标时间,降低低血糖发生率,值得在临床推广应用.
  • Ramírez-Zamora S, Méndez-Rodriguez M L, Olguin-Martinez M. Increased erythrocytes by-products of arginine catabolism are associated with hyperglycemia and could be involved in the pathogenesis of type 2 diabetes mellitus [J]. PLoS One, 2013(6):e66823.
    Goldstein DE, Nuthun D, Little R R. Test of glyceminin diabetes [J]. Diaetes Care, 2004, (12):1761.
    Weng J P, Li Y B, Xu W. Effect of intensive insulin therapy on β-cell function and glycaemic control in patients with newly diagnosed type 2 diabetes:a multicentre randomised parallel-group trial [J]. LANCET, 2008, (9626):1753.
    张具仓, 文发魁, 韩静. 胰岛素泵强化治疗新诊断的2型糖尿病的疗效观察 [J]. 中国糖尿病杂志, 2011, (10):758.
    Grady M, Campbell D, Macleod K. Evaluation of a blood glucose monitoring system with automatic high-and low-pattern recognition software in insulin-using patients:pattern detection and patient-reported insights [J]. J Diabetes Sci Technol, 2013(4):970.
    王玲, 窦怀宝, 朱琳璐. 短期胰岛素泵强化治疗对新诊断2型糖尿病的临床观察 [J]. 实用老年学杂志, 2012(3):221.
    Didangelos T, Iliadis F. Insulin pump therapy in adults [J]. Diabetes Research and Clinical Practice, 2011, (Suppl 1):S109.
    Cummins E, Royle P, Snaith A. Clinical effectiveness and cost-effectiveness of continuous subcutaneous insulin infusion for diabetes:systematic review and economic evaluation [J]. HEALTH TECHNOLOGY ASSESSMENT, 2010, (11):170.
    于学满, 赵晓娟, 王璐. 胰岛素治疗与胰岛B细胞休息的相关性研究 [J]. 中国实用内科杂志, 2005(4):313.
    喻明, 吴松华, 周健. 新诊断2型糖尿病患者治疗前后血糖水平的动态变化 [J]. 中国实用内科杂志, 2005, (25):881.
    Kotwal N, Pandit A. Variability of capillary blood glucose monitoring measured on home glucose monitoring devices [J]. Indian J Endocrinol Metab, 2012, (Suppl 2):S248.
    Lane J E, Shivers J P, Zisser H. Continuous glucose monitors:current status and future developments [J]. Curr Opin Endocrinol Diabetes Obes, 2013(2):106.
    Pearce K L, Noakes M, Wilson C. Continuous glucose monitoring and cognitive performance in type 2 diabetes [J]. Diabetes Technology & Therapeutics, 2012, (12):1126.
    管晓峰, 黄淑玉, 徐文浩. 胰岛素泵联合动态血糖监测系统治疗糖尿病疗效观察 [J]. 内科急危重症杂志, 2007(3):147.